Option A:
Unshielded Cable 25 ft. maximum distance between power supply to the beginning of the DPI
The AISPIRE In wall rated 20 AWG unshielded 3-condcutor cable can be used to wire between a power supply-DMX LED Controller to the beginning of the DPI up to 25 ft. Smaller gauge wire number (bigger conductor) can be used, but the maximum run length limitation remains at 25 ft. due data communication distortion if it’s run over 25 ft. (See FIG. 3) Wire color connection is shown in Table 1.
Table 1:
Fig 3:
Option B:
Shielded data Cable 90 ft. maximum distance between power supply to the beginning of the DPI
A shield data cable shall be used to connect between the power supply-DMX LED Controller to the beginning of the DPI up to 90 ft.
ICE cable model number: Control Yellow is recommended. Please review the product Specification Sheet.
For Plenum spaces, ICE cable Control Yellow Plenum is recommended.
Both drain and common conductor wires shall be connected to a black terminal of DMX LED Controller. Another end shall be connected to the black wire of connector cable. The signal conductor shall be connected to the white terminal of DMX LED Controller. Another end shall be connected to
the white wire of connector cable. The power carrying cable can be used either shielded or unshielded cable. The bigger conductor yields less voltage drop. The +24VDC polarity shall be connected to the red terminal on DMX LED Controller. Another end shall be connected to the red wire of connector cable. The -24VDC or common conductor wire shall be connected to a black terminal of DMX LED Controller. Another end shall be connected to the black wire of connector cable.
A2L15-WL (5-3 low voltage wiring box) may be used to connect between 5 wires of shield cable to 3 wires of DPI connector.